MICRO CONECTOR® Technical Instructions

Dental Office Impression Procedure

Click here for Laboratory Procedure

Using the Micro-Conector gauge, select the correct tissue cuff hieght
1mm Blue  2mm Green  3mm Red  4mm Yellow

Clip the plastic transfer coping "PEEK" onto the Micro-Conector

Take a silicone impression
(Hardness minimum 55 Shore)

*Note: Transfer coping "PEEK" is designed to remain on the Micro-Conector when impression is removed.


Laboratory Procedure

Screw the Micro-Conector to the analog

Clip the plastic PEEK coping onto the Micro-Conector

Apply a small drop of cyano-acrylic glue to the top of the PEEK coping

Reposition the PEEK coping with the analog into the impression according to the color coded gingival height instruction of the dentist

Fabricate the master model

Using the Micro-Conector gauge, select the correct tissue cuff height

1mm Blue
2mm Green
3mm Red
4mm Yellow

Screw the Micro-Conector to the analog

Screw the Micro-Conector to the analog

Clip the low profile, spherical metal female
to the analog

Proceed with wax-up for denture try-in

After try-in, fill the inside of the metal female with light silicone and reposition onto the master model

Eliminate excess silicone

Complete acrylic denture as usual

A metal sub frame can be manufactured if desired